MACHINE COMPONENTS
6
3
7
4
5
9
1. ON/OFF Switch
2. Drain Hose
3. Intake Hose Connector
4. Discharge Hose Connector
5. 76L (20 Gal) Recovery Tank
6. Recovery Tank Cover
7. Cover Latches
8. 254 mm (10 in) Stair Climbing Wheels
9. Swivel Casters
NOTE: See Parts List section for standard
accessories.
SETUP AND OPERATION
FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
1. Carefully check carton for signs of damage.
Report damages at once to carrier. Machine is
fully assembled and ready for use.
Flood Pumpert Plus (02- -06)
2. Check that float shutoff screen and filter bag are
installed in recovery tank (Figure 1).
1
2
ATTENTION: Do not operate machine without
screen and filter bag in place, vacuum motor and
pump damage will result.
Use Flammable Liquids Or Operate Machine in Or
Near Flammable Liquids, Vapors Or Combustible
8
Dusts.
3. Connect 5 M (15 ft) hose to intake connector and
8 M (25 ft) hose to discharge connector (Figure 2).
Place opposite end of discharge hose outside or to
drain that will handle large volume of water.
NOTE: Do not exceed 31 M (100 ft) of intake hose.
For best performance, length of 8 M (25 ft) is
recommended. Discharge hose can be any horizontal
length, do not raise discharge hose beyond 2 M (8 ft).
4. Attach accessory tool to intake hose if desired.
5. Connect equipped extension cords to pig tails on
machine and plug each cord into a separate
grounded circuit (Figure 3).
ATTENTION: Be certain to use a separate circuit
for each power cord to prevent circuit overload
(machine draws 17 amps).
FIG. 1
WARNING: Fire Or Explosion Hazard: Never
FIG. 2
OPERATION
Intake Hose
Discharge Hose
5