Blower Feature; Automatic Suction Shut-Off; Troubleshooting - Shop-Vac 87P Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. for best results when vacuuming large quantities of liquids containing
debris, it is recommended using the foam sleeve. With tank cover in
an upside down position, slide foam sleeve down over lid cage pulling
until foam sleeve completely covers lid cage (figure 72). foam sleeve
must be positioned on the InSIde of groove around the lid cage.
6. Make sure inlet deflector is fully inserted into deflector guide on inside
of tank. If it is not, install inlet deflector by sliding it downward into slot
on deflector guide (figure 73). NOTE: hose must be removed before
inlet deflector can be inserted into or removed from deflector guide.
Opening on inlet deflector can face either side of tank. Inlet deflector
should always be in place for any type of cleaning.
7. Misting in exhaust air or dripping of liquid around the lid may occur
if the filter becomes saturated. Remove filter and allow to dry or replace with another dry
filter.
8. Turn unit off immediately upon completing job or when tank is full and ready to be emptied
(refer to emptying Liquid Wastes). Raise the hose to drain any excess liquid into the tank.
9. The interior of the tank and filters should be periodically cleaned. (To clean the cartridge
filter, refer to Cleaning under Installing the Cartridge filter).
Cleaning the foam Sleeve:
1. Always disconnect the plug from the wall receptacle before removing the tank cover. Place
tank cover in an upside down position. Remove foam sleeve by sliding it up and off the lid
cage.
2. Shake excess dust off foam sleeve with a rapid up and down movement.
3. hold foam sleeve under running water for a minute or two, rinsing from the inside. A water
wash is not always required (depending on the condition of the foam sleeve).
4. Gently wring out excess water. Blot foam sleeve with a clean towel, and allow to dry. The
foam sleeve is now ready to be reinstalled.
NOTE: WeT PICk uP ACCeSSORIeS ShOuLd Be WAShed PeRIOdICALLy, eSPeCIALLy AfTeR
PICkInG uP WeT STICky kITChen ACCIdenTS. ThIS CAn Be ACCOMPLIShed WITh A WARM
SOLuTIOn Of SOAP And WATeR.
PUMP OPERATION
WARNING
– TO REDUCE THE RISk Of ELECTRICAL
SHOCk, DO NOT DIRECT DISCHARGE STREAM AT UNIT!
WARNING
– THE CARTRIDGE fILTER IS NOT
COMPATIBLE WHEN UTILIZING THE PUMP PICk UP ASSEMBLy.
NOTE: Not for use as a sump pump. Do not leave unit unattended while in use.
Set-up:
1. Always disconnect the plug from the wall receptacle before removing the tank cover.
2. Remove tank cover and any filters other then foam sleeve.
3. Remove ALL dirt and debris found in tank.
4. If not already done, install foam sleeve and make sure inlet deflector is fully inserted into
deflector guide following the instructions and illustrations under Wet Pick up Operation.
5. Insert tube into pick up cage and push until tube comes to a stop (figure 74).
6. Take pick up assembly from step 5 and insert tube into hole in bottom of lid cage and push
until assembly comes to a stop (figure 75). NOTE: do not attempt to pump without pick up
cage in place or screen on pick up cage. failure to do this could result in damage to pump.
7. Replace tank cover and secure latches.
8. Remove outlet-fitting cover and connect a standard garden hose (not included) to outlet fit-
ting (figure 76). Place other end of garden hose at suitable drain.
9. Attach the 2-1/2" hose to tank inlet.
10. Place wet pick up elbow on the hose end and attach desired accessory to elbow (figure
77). elbow must be in place during pump operation to prevent overfilling of unit. do not
attempt pump operation without elbow in place. do not cover bleed hole in elbow. failure
to follow these precautions will result in overfilling of unit and misting through exhaust port.
74
75
Operation:
1. Plug vacuum in and push the On switch button. NOTE: Switch will automatically return to a
neutral position.
2. Start vacuuming up the liquid. The unit will automatically begin pumping when at least 4"
of liquid is in the bottom of the tank.
3. The unit will automatically shut off when full.
4. To empty a full tank, remove vacuum hose from the liquid. do not lift hose to empty liquid
into tank. This will cause the unit to overfill and misting through the exhaust port will occur.
5. The On/Off switch must be manually held in the On position for approximately 10-15
seconds to allow the water level to be reduced sufficiently and then pumping will continue
automatically. Once the vacuum is pumping manually release the switch and allow it to
operate on its own. ATTENTION: HOLD SWITCH IN ON POSITION ONLy UNTIL WATER
STARTS TO fLOW. RELEASE SWITCH WHEN PUMPING BEGINS.
6. The unit will continue to discharge liquid until there is about 4" (10 cm) left in the tank.
NOTE: If The unIT ShuTS Off BefORe LIquId IS PuMPed OuT RePeAT STePS 5 And 6.
7. When the level of liquid lowers and the unit stops pumping continue vacuuming up the liq-
uid.
8. Repeat steps 4-7 when vacuum is full and shuts off.
9. After the job has been completed, allow liquid to be pumped until unit has stopped pumping
and there is 4" of liquid remaining in tank.
10. Make sure unit is in the off position.
11. disconnect plug from the wall receptacle and remove tank cover.
72
73
76
77
12. Remove and clean pump pick up assembly
13. empty remaining liquid from tank (refer to emptying Liquid Wastes).

BLOWER fEATURE

This vacuum can be used as a powerful blower. To use your unit as a blower unscrew blower port cover
located on the backside of the motor housing (figure 78). The blower port cover is equipped with a
retaining strap to prevent loss of the port cover while blower is in use. Clear hose of
any obstructions before attaching to blower port. Insert hose end with locking-nut
into blower port on rear of unit and tighten. do not over-tighten. Caution should be
used when using as a blower due to the powerful force of air when using certain
attachments.
NOTE: for maximum performance, when vacuuming, remove blower port
cover.
WARNING
– ALWAyS WEAR EyE PROTECTION TO PRE-
VENT ROCkS OR DEBRIS fROM BEING BLOWN OR RICOCHETING INTO
THE EyES OR fACE WHICH CAN RESULT IN SERIOUS INjURy.
EMPTyING LIQUID WASTES fROM THE TANk
Not all units are equipped with tank drains. Follow the instructions, which apply
to your specific unit.
Without Tank Drain
Liquid waste may be emptied by removing the tank cover. To empty, stop the motor and
remove the plug from the wall receptacle. Remove the tank cover and deposit the liquid
waste contents in a suitable drain. After tank is empty, return the cover to its original posi-
tion. To continue use, plug the cord into the wall receptacle and turn the unit on.
With Tank Drain
Liquid waste may be emptied by removing the tank drain. To empty, turn unit off and remove
plug from wall receptacle. Remove the drain cap and deposit the liquid waste contents in a
suitable drain. After the tank is empty, return the drain cap to its original position. To con-
tinue use, plug the cord into the wall receptacle and turn the unit on.

AUTOMATIC SUCTION SHUT-Off

The cleaner is equipped with an automatic shut off feature when picking up liquids. As the
level of the liquid rises an internal float electronically shuts the unit off when liquid reaches the
tank capacity. At this point, the liquid must be emptied to allow vacuuming to continue. Refer
to sections above.
NOTE: If ACCIdenTALLy TIPPed OVeR, The VACuuM COuLd LOSe SuCTIOn. If ThIS
OCCuRS, PLACe VAC In uPRIGhT POSITIOn And TuRn SWITCh Off. ThIS WILL ALLOW The
fLOAT TO ReTuRn TO ITS nORMAL POSITIOn, And yOu WILL Be ABLe TO COnTInue OPeRA-
TIOn.
LUBRICATION
no lubrication is necessary as the motor is equipped with lifetime lubricated bearings.
Before storing your vacuum cleaner the tank should be
emptied and cleaned. The power cord can be wrapped
around the cord wraps provided on the tank cover on
rear of unit (figure 79). Accessories may be stored
in the tool holder (not standard with all models). If a
hose holder (not standard with all models) has been
included, assemble as follows. Install hose holder end
with fastener onto hose. Slide or snap fastener into notch securing in place. Remove extension
wands and/or accessory from end of hose and place hose end into open end of hose holder to
secure hose in place for easy storage (figure 80). The cleaner should be stored indoors.

TROUBLESHOOTING

Trouble
Possible Cause
Suction weakens or
Clogged filter
cleaner runs hot
Air leak
Obstruction in hose
or nozzle
Misting in the
Saturated filter
exhaust air
Mounting ring
foam sleeve
falling off
incorrectly positioned
WARNING
– If ANy Of THE MOTOR HOUSING PARTS
SHOULD BECOME DETACHED OR BROkEN, EXPOSING THE MOTOR OR ANy
OTHER ELECTRICAL COMPONENTS, OPERATION SHOULD BE DISCONTINUED
IMMEDIATELy TO AVOID PERSONAL INjURy OR fURTHER DAMAGE TO THE
VACUUM. REPAIRS SHOULD BE MADE BEfORE REUSING THE VACUUM.
THREE yEAR HOME USE WARRANTy
your Shop-Vac
®
vacuum cleaner is warranted for normal household use, in accordance with
the user Manual, against original defects in material and workmanship for a period of three
STORAGE
79
Remedy
Brush dirt from filter. If condition continues,
change filter.
Check all fittings for tight fit (nozzles, hose, etc.)
Check that tank cover is sealed properly.
Check nozzle, hose, etc. for obstructions, and
remove if present.
Replace saturated filter with a dry filter.
Position foam sleeve on the outside of
groove around lid cage.
78
80

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

90p serie92p serie

Tabla de contenido