Location and Installation

The cabinet should be placed in a room that is dry and suffi ciently ventilated. To operate effi ciently it should not be positio ned
in direct sunlight or near warm appliances. Please note that optimal cabinet performance is obtained at an ambient temperature
between +16 °C and +35 °C.
Freezer,
Chiller:
By placing the cabinet in an environment with high air humidity, it may be necessary to acquire extra equipment for
evaporation of the drip water in the pan near the compressor.
The cabinet can be installed freestanding against a wall.
Important
The cabinet must have suffi cient ventilation and free air circulation beneath, above and behind the cabinet. The legs under the
spacers at the rear of the cabinet will help ensure suffi cient air space.
Remove the appliance from the packaging. Make sure that all pr otective plastic fi lm and coatings are thoroughly removed from all
surfaces. To prevent injury or damage to the unit, we recommend that the appliance should be unpacked and set up by two people.
The appliance should be placed on a solid level fl oor to reduce noise and vibration. Level the appliance by adjusting the screw feet.
Check that the power supply and voltage used comply with the details on the rating plate. The plug must be accessible after installation
Correctly connect and disconnect the plug. When inserting ensure the plug is fully engaged. When unplugging do so by holding the body
of the plug. Never pull the supply cord directly.
If the appliance is to be shut down for long period, switch it off and disconnect the plug from socket outlet. Clean the appl
the door open to prevent odour.
Important! For your personal safety, this appliance must be properly grounded (earthed). This appliance is equipped with a co rd having a
grounding wire with a grounding plug. The plug must be inserted into an outlet that is properly grounded and installed. Consult a qualifi ed
electrician or service center if you do not completely understand the grounding instructions. If doubt exits as to whether the
properly grounded, have a qualifi ed electrician check the circuit to make sure the outlet is properly grounded.
If the cable does not reach the nearest socket, either rearrange your store layout or ask a qualifi ed electrician to fi x a ne w socket.
If power is cut off, wait for at least 3 minutes before restarting the appliance to avoid damaging the compressor.
Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operat ion.
Note: Before using the appliance for the fi rst time, clean the shelves and interior with soapy water.

Power Requirements

The cabinet is intended for connection to an alternating current. The connection voltage (V) and frequency (Hz) are shown on th e nameplate
in the cabinet. The power connection is made using a three-pin plug to a wall socket. Any requirement for earthing from the loc al power
supply must be met. The cabinet plug and wall socket should then give a correct earthing. If you are in doubt, contact your loc al supplier or
authorized electrician.
Warning - This appliance must be earthed
The fl exible cord fi tted to this appliance has three cores for use with a 3-pin 13 Amp plug. If a B.B. 1363 (13 Amp) fused
plug is used, it should be fi tted with a 13 Amp fuse or a moulded right-angled Schuko plug. Note the plate with a hole in
it between and above the two pins - this connects to French and Belgian sockets, which have an earth pin that sticks out.
Running in a slot coming from that plate is a continuation strip from the plate. Other European countries use a socket with
a scrolled metal connector emerging from the side which mates with that strip. This ensures that the Schuko can be used
in most mainland European countries.
Important
The wires in this mains lead are coloured in accordance with the following code:
Green-and-yellow: earth
Blue: neutral
Brown: live
The colours of the wires in the mains lead of this appliance might not correspond with the coloured markings identifying the te rminals in your
plug. Proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the plug which is marked „E", marked by the ea rth symbol
or coloured green-and-yellow. The wire, which is coloured blue, must be connect ed to the terminal, which is marked with the letter "N", or
coloured black. the wire which is coloured brown must be connected to the terminal which is marked with the letter „L" or colou red red.