LOAD 2 DETECTION
The scale displays LOAD2.
Load a standard weight, and press
. 00000 shows.
Press
or
and
, to modify the digit. Press
Press
, to input the decimal point.
Keep the load stable and press
, to display the weight code 34567.
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically enters Load3 Detection.
LOAD 3 DETECTION
The scale displays LOAD3
Load a standard weight, and press
. 00000 shows.
Press
or
and
, to modify the digit. Press
Press
, to input the decimal point.
EN
Keep the load stable and press
, to display the weight code 45678.
Wait until the weight code is stable. Press
Once the detection finished, the scale automatically saves and exits the Calibration mode.
Problem
Possible Cause
discharged / defective battery
not power-on after
is pressed
defective
defective power cable
defective mainboard
display flashes
discharged battery
scale is disturbed
no action taken after key
pressed
defective key
REV. V 2016
or
, to move the digit. Input weight value.
, to start the weight detection.
or
, o move the digit. Input weight value.
, to start the weight detection.
Suggested Solution
check batteries and charge / exchange
the batteries
press harder and keep pressing 2sec
key
open front panel, check power cable
contact service representative
charge / exchange the batteries
Turn off and then turn the scale on
again
contact service representative
30
Problem
Possible Cause
load in motion
weak Anti-Motion
weight reading not stable
damped loadcell or mainboard
defective mainboard
weight reading not zero
discharged batteries
when no load
load-cell stressed too long
defective loadcell
large error in weight
scale not zeroed before applying
reading
load
wrong unit
scale requires calibration
defective loadcell or mainboard
short remote controlling
discharged / defective remote
distance
battery
REGULAR CONTROL OF THE DEVICE
Control regularly that the device doesn´t present any damage. If there is any damage, please stop using the
device. Please contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
Invoice number and serial number (the latter is to be found on the technical plate on the
device).
If relevant, a picture of the damaged, broken or defective part.
It will be easier for your customer service clerk to determine the source of the problem if you give
a detailed and precise description of the matter. The more detailed your information, the better the
customer service will be able to solve your problem rapidly and efficiently!
CAUTION: Never open the device without the authorization of your customer ser-
vice. This can lead to a loss of warranty!
REV. V 2016
Suggested Solution
keep load stable
change Anti-Motion level
dry loadcell or mainboard
contact service representative
charge / exchange the batteries
offload the weight
contact service representative
manual Zero scale before loading
switch to correct unit
calibrate scale
contact service representative
replace remote controller batteries