Taking out of operation
1.
Switch off the high pressure cleaner
2. Cut off the water supply
3.
Open the safety trigger gun catch briefly until the pressure is released
4. Apply safety catch on the trigger gun
5.
Remove high pressure hose and safety trigger gun
6. Emptying high pressure pump: Hold high pressure hose and switch
motor on until water jet stops escaping at the outlet.
7.
Pull the plug from the socket
8. Clean high pressure hose and wind up without loops
9. Clean and wind up the power supply cable
10. Clean the water inlet sieve
11. Store high pressure cleaners in frost-free rooms in winter
46
Due to their small base, the compact and
mobile Kränzle high pressure cleaners are
easy to store.
Small repairs - do it yourself
Problem
No water from nozzle although the high pressure cleaner is running.
Cause
Most likely the nozzle is blocked.
Pull plug from socket prior to starting any repair work!
No or very little water from the lance.
Proceeding:
Switch off the high pressure cleaner. Pull
plug from the socket. Operate safety trigger
gun catch several times to decrease the
pressure.
Unscrew safety trigger gun and lance first,
then rinse high pressure hose to remove
possible soiling.
Check water inlet filter for soiling.
If the problem still exists, take wire (paper
clip) and push through nozzle opening.
If cleaning by means of a wire is not
successful, replace lance.
GB
47