Contact Opening; Operation; Remove Pump Lid - Jandy Pro Serie Manual De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 12
ENGLISH

3.2.6.2 Contact Opening

If the pump speed is below 1725 RPM, the Auxiliary
Load contact is opened. Contact openings are always
immediate.
Section 4.

Operation

4.1

Remove Pump Lid

1. Make sure that the pump is turned off.
2. Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the
variable-speed pump electrical circuit before starting
the procedure. Failure to comply may cause a shock
hazard resulting in severe personal injury or death.
Figure 10. Disengage Lock Ring
Jandy
Pro Series VS PlusHP Pumps
®
Rotate locking ring
counter clockwise
Align START
with port
|
Installation & Operation Manual
Figure 11. Remove Pump Lid
WARNING
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fi re, electric shock, or
injuries to persons, Zodiac® Pumps must be installed
in accordance with the National Electrical Code
(NEC
), all local electrical and safety codes, and the
®
occupational Safety and Health Act (OSHA). Cop-
ies of the NEC may be ordered from the National
Protection Association, 470 Atlantic Ave., Boston,
MA 02210, or from your local government inspection
agency.
In Canada, Zodiac Pumps must be installed in accor-
dance with the Canadian Electrical Code (CEC).
3. Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump. If
the pump is installed below water level, ensure all
necessary isolation valves are closed to prevent
pool water from reaching the pump.
4. Turn the locking ring counter-clockwise until
the 'START' markings align with the ports. See
Figure "Figure 10. Disengage Lock Ring"
5. Carefully lift to remove the lid with locking ring.
Locking Ring
Lid
Seal
Basket
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vs plushp vsphp270jepVs plushp vsphp270aut

Tabla de contenido