Voltage Measurement - Bosch KTE 001.05/001.06 Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.3

Voltage measurement

456043P
Voltage measurements are necessary for
checking
- the charging system (generator, regula-
tor, battery)
- the starting system (battery, starter)
- consumers (lighting).
4.3.1 Connections
Any work on the ignition system
may only be carried out when the
engine is at a standstill and the
ignition is disconnected (see
also "Information for your
safety", page 17).
The yellow clip is connected to the contact
of the component to be measured (+)
The green clip is connected to earth (-)
4.3.2 Setting
Set the measurement-mode selector
switch to the desired measuring range.
4.3.3 Reading off
Voltage in volts
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kte 001.03/001.07

Tabla de contenido