ATTENTION
Attention: This machine has a safety system that automatically switches the
machine off in case of overheating. If this occurs, disconnect the machine. Allow
the machine to cool down for approximately 3 minutes before reconnecting it.
If this problem occurs more often, please contact your dealer.
C
A A
WATER DRAINAGE
The red light » will switch on when the reservoir is full. A safety system ensures
that the machine then switches itself off. Simply remove the reservoir to drain the
water (fig. A).
EXTERNAL DRAINAGE
If desired, it is possible to fit a drainage hose to the machine. Follow the steps
below:
1
B B
2
3
4
5
Seal the drainage spout with the appropriate plug when you wish to operate
the machine normally again, without a drainage hose.
D
OPERATING THE HEATER
When the machine is connected, select the desired air temperature with the
ventilator selector switch ²:
1
4
28
Adjusting the ventilator speed reduces the noise level. However, this also causes
a slight loss of capacity as the machine works with reduced power at this setting.
We recommend that the machine be set to operate on reduced power if the
humidity level is lower than 60% in order to generate the optimum power
consumption/benefit ratio.
Remove the reservoir from the machine.
Remove the plug from the end of the drainage spout.
Connect the drainage hose to the spout (fig. B). The drainage hose is available
at your dealer's.
The hose is led out of the hole in the bottom of the machine.
Install the reservoir in the machine.
Air circulation
Select the desired airtemperature with de ventilator selector switch
Warm air.
Hot air.
Regulate the thermostat
-
turn the thermostat button
-
when the room or area has reached the desired temperature, turn
the thermostatbutton back until you hear a click.
-
the thermostat will turn on and off automatically when the
temperature either drops below or exceeds the required level.
Hot air
Extremely hot air
as follows:
clockwise to the 'max' setting.
: