Reverse osmosis unit for the desalination of tap water with a daily output of up to 400 litres. With
this unit, you can remove the inorganic and organic substances, dissolved in your tap water, to a percentage of
about 99% without adding any chemicals.
1. Delivery
The reverse osmosis system platinum line plus is supplied with three large 10" filter housings. The filter
cartridges (activated carbon, fine filter and demineralization resin) can easily be replaced. The fitted pressure
gauge will display the operation pressure at any time. All components, the prefilter housings and the membrane
module are mounted onto a stable powder-coated bracket. The unit has a high pressure pump and a flushing
valve and therefore, can achieve a high ratio of pure to waste water output up to 1:1. The salt removal rate is
up to 99%. Due to the fully automatic back flushing and continuous monitoring of the pure water, the unit
requires very little maintenance.
It consists of the following parts:
- Fine filter 10" with 5 µm pore size
- Combined filter (fine and activated carbon filter)
- Reverse osmosis module 400 litres/day with a first class synthetic membrane (Polyamide/Polysulfon, TFC)
with a daily output of up to 400 litres (5)
- Flush valve: at this valve, the permeat/concentrate ratio is adjusted to 1:2 (to maximum 1:1).
- Demineralization filter
- 24 V DC high pressure pump incl. control unit
- Tap water connection fitting (3/4") incl. pressure tube
2. Set-Up
The reverse osmosis system is mounted on a bracket. This should be fixed on the wall
connection. Then, connect the tubes. To avoid any failures, follow the instructions carefully:
Fig. 1: Connecting the tube fittings
6
Operation manual ENG
Tube fittings:
1. Remove the blue lock ring.
2. Insert the hose to a complete stop into the fitting.
3. Refit the lock ring.
4. Pull the hose back as a test that it is located.
Removing the tubes:
1. Remove the blue lock ring.
2. Push the ring back towards the fitting with a finger nail. Now, you can remove
the tube.
3. Please don't forget to refit the lock ring.
preferably near a water

Publicidad