Display
T.D.S.: Total Dissolved Solids
-
FULL: Not applicable since the unit is supplied without storage tank
-
WORK: In operation
-
POWER: Power is connected
-
SOURCE: Water is connected
-
FLUSH: Back flush
-
Now, the water will start to flow from the waste water outlet (14). After some time, also purified water flows
out of the pure water outlet (2), however, at a lower flow rate. Low pressure or temperatures reduce the pure
water volume. The pure water, produced in the first 2 hours, has to be discarded as it may contain residues of
the disinfectant liquid which has been used in the module for storage. After 2 hours, the water can be used.
Fig. 4: platinum line plus
Available spare parts: Please refer to
The display shows the remaining salt content of the osmosis water. If the value rises, the resin has to be replaced
in the demineralization filter. To do so, turn the unit off, open the 10" housing with the appropriate wrench,
remove the cartridge and refill it. Then close the 10" housing firmly and restart the system.
8
www.aqua-medic.de.
1.
Water inlet
2.
Pure water outlet
3.
Flush valve
4.
Module's screw cap
5.
Module incl. membrane
6.
Prefilter housing for fine filter
7.
Prefilter housing for activated
carbon filter
8.
Demineralization filter
9.
High-pressure pump
10. Control unit
11. Power supply
12. Magnetic valve
13. High-pressure button
14. Waste water outlet
15. Magnetic valve
16. Low-pressure button
17. Pressure gauge
18. Mounting bracket
19. TDS sensor