Components; Commissioning - Schneider Airsystems SLA 8 A Manual De Instrucciones

Ocultar thumbs Ver también para SLA 8 A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
GB
SLA
CAUTION
Tripping hazard!
Air hoses laid on the ground
X
Avoid or pay close attention!
NOTICE
Avoid placing the hose under extreme
loads and handling inappropriately!
X
Do not leave the compressed air tool
hanging!
X
Do not drive over, crush or clamp the
hose!
X
Do not pull over sharp edges.
X
Do not expose the hose to oil or high tem-
peratures!
X
Avoid using excessive force!
L
• Protect yourself and other persons, ani-
mals, property, and the environment by
taking the necessary protective measures
and being trained in use of the devices to
prevent harm to your health, property
damage,
financial
harm or risk of accident.
• Be calm and focused and ensure proper
operation.
• Repairs may be carried out only by
Schneider Druckluft GmbH or its approved
service partners.
• Prohibited: manipulation, inappropriate
use, temporary repairs, removal or use of
damaged safety equipment, operating a
malfunctioning system, use of non-original
spare parts, working without protective
equipment, maintaining, repairing or leav-
ing a pressurised machine unattended, us-
ing other / unsuitable lubricants, smoking,
naked flames, removing stickers.
7

Components

01
Retaining bracket
02
Connection hose with plug nipple
03
Quick-action coupling
04
Stopper
8
loss,
environmental
05
Air hose
06
Cover
07
Screw
8

Commissioning

Prior to commissioning:
1. Refer to the technical data, illustrations,
part numbers and read all safety instruc-
tions.
2. Carry out a visual inspection.
3. Do not use below 5° C.
Assembly:
1. Drill the holes for the retaining bracket at
the correct distance from one another
(Fig. 2a or Fig. 2b, depending on model).
2. Secure the retaining bracket (item 01)
using screws designed to bear the weight
of the reel and withstand any tensile
forces that occur.
3. Attach the hose retractor to the retaining
bracket (Fig. 2a / Fig. 2b) with the hose
leading out from the top (Fig. 3a).
4. Activate the compressed air supply via
the upstream shutoff valve. Make sure
that the hose is long enough for the unit
to swivel 180°.
Adjusting and commissioning:
1. Take hold of the air hose (item 05) in
front of the stopper (item 04) and pull to
the required length.
2. The hose reel locks every 50 / 80 cm de-
pending on the model and the hose is re-
tained in that position.
3. Connect the compressed air tool to the
quick-action coupling (item 03) as shown
in Fig. 1a.
Winding up:
1. Disconnect the compressed air tool from
the quick-action coupling (Fig. 1b).
2. Pull the air hose approx. 30 cm beyond
the locking position and then slowly re-
lease at a steady rate.