8.3.4 Hilti injection anchor (2.65 HDL SST, 2.70 HDL SST, 2.80 HDL SST)
Quality of concrete Normal armouring
subject to alterations!
Adhesive and anchor rod:
Art. Hilti:
Seismic / filling set or suitable filling method
Effective anchoring depth:
Material:
Registration number:
Issued / valid:
Anchor plate:
Ground:
Installation:
Reinforcement:
Observe necessarily the installation description of the dowel manufacturer. Use longer dowels with ver-
sion with floor pavement and tiles.
It is possible to use equivalent injections dowels (with license) of other manufacturer but observe their
regulations.
OPI-POWER LIFT HDL 6500 SST DG-7000 SST DG-8000 SST DG - HYMAX H 6500 DG-H 7000-V1.0-DE-EN-FR-ES-IT
118
HIT-HY 200-A + HIT-V (5.8) M16
387066 HIT-V-5.8 M16x300 / 2022696
h
= 190.0 mm
ef
5.8
ETA 11/0493
2/3/2017 | -
l x x ly x t = 850.0 mm x 525.0 mm x 30.0 mm
C racked concrete, C20/25, fc,cube = 25,00 N/mm2; h = 226,0 mm,
Temp.: 24 °C (max. 40 °C)
Drilled hole: hammer-drilled, dry
N o reinforcement or rod spacing ≥ 150 mm (each diameter) or ≥ 100
mm (diameter ≤ 10mm)
No edge length reinforcement
Reinforcement is provided to prevent cracks according to EOTA TR
029, 5.2.2.6.