2. DESCRIPTION (Fig. 1)
1. Control Panel.
2. 360º outlet of fi ltered air.
3. Light indicator of air quality.
4. Air quality sensors / RH% / T ºC.
5. 360º inlet of unfi ltered air.
6. Drum fi lter location.
7. Internal access for fi lter change.
3. COMMISSIONING
Follow the steps below in order:
• Remove the appliance from its packaging. Do not leave the packaging within the reach of children and deposit it in
compliance with current recycling regulations.
• ¡ATTENTION! To protect the fi lter, it comes from the factory inside the appliance and protected in a plastic bag THAT
MUST BE REMOVED BEFORE FIRST USE.
• You can carefully lay the appliance on a soft surface so as not to damage it.
• Access the drum fi lter (Fig.1 position 7) by turning the cover located on the base counterclockwise (Fig. 2).
• Remove the fi lter inside the purifi er and remove the protection bag.
• Place the fi lter back into the purifi er
• ¡ATTENTION! Do not leave the plastic bag within the reach of children.
• Replace the plastic cover by turning clockwise.
• Connect the connection cable to the base of the appliance (Fig.3).
• Before connecting the power cable to the mains, make sure that the supply voltage matches the one indicated on the
nameplate of the appliance.
• Make sure the appliance is placed fi rmly on the fl oor.
4. CONTROL PANEL (Fig. 4)
Air quality PM2,5 (μg/m
Light strips refl ecting Air quality
(flashing if It is time to replace the filter)
PM2,5 inspection/ ultraviolet light
Levels of Air quality
(perfect - good - normal - poor)
ON/OFF: When the appliance is connected to the network, the ON/OFF button lights up red and remains in stan-
dby mode. By pressing ON/OFF the air purifi er starts by default in SMART MODE.
SMART MODE: The air purifi er automatically adjusts the fi ltering speed according to the air quality. With this
operating mode activated, the UV lamp (Illuminated UV symbol) is also continuously activated.
If the user presses MANUAL MODE or NIGHT MODE, the smart mode will be deactivated.
MANUAL MODE: Regardless of air quality, you can choose up to four fi ltration rates 1 (Slow) - 2 - 3 - 4 (Fast). The
corresponding indicator light will indicate the chosen speed.
SLEEP MODE: The appliance will operate at the lowest speed to minimize noise and the control screen will auto-
matically turn off to preserve the darkness of the room. Pressing any option (except ON/OFF) the appliance will
exit the night mode and return to the state prior to the selection of the Sleep mode.
3
)
RH% Humidity level
Cº Temperature
Filtration speed