3.The motor access hatch must be at least 70 x 45 cm. minimum, so that tools will be required to open it
10
(Fig. 2).
4.The grille on the access hatch must be at least 200 cm in size. It will have openings that prevent the
penetration of a rod with a diameter of 8 mm (Fig. 2).
Fig-2
2- SKIRTING
Installation with skirting is described in the INSTALLATION INSTRUCTIONS corresponding to each
bath model, which are enclosed with the bath.
This system avoids the need to provide an access hatch and ventilation grille. Access to the
hydromassage bath equipment for maintenance purposes is achieved by removing the skirting, and
ventilation is provided through the gap between the skirting and the floor. Under no circumstances
should this gap be sealed.
The bath skirt will always be firmly fitted, requiring a tool for its removal. This tool should only be handled
by qualified personnel (corresponding Technical Assistance Service).
PLUMBING INSTALLATION
1. The plumbing installation must comply with the corresponding regulations applicable in each country.
2.For the installation of taps, please consult the INSTALLATION INSTRUCTIONS corresponding to
each bath, which advise on how best to position them.
3 .The automatic plug must be connected to the effluxion system by means of an elastic joint.
Installation manual - EMMA
2