Electrical Installation - GALA EMMA Manual Del Instalador

Ocultar thumbs Ver también para EMMA:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation manual - EMMA
24 11

ELECTRICAL INSTALLATION

The electrical installation must comply with low voltage regulations and with the corresponding
regulations of each country.
1. Installation
Electrical connections must provide a minimum of Ipx5
protection within volume 1. A connecting box (in accordance
with the protection established) is recommended. Care must
also be taken to make this connection at a height of more than
20 mm above the floor.
No part of the bath should be situated above it while in use.
Sections containing live parts, except those powered by a very
Volume 0
low safe voltage that does not exceed 12 V, must be inaccessible
to a person inside the bath.
No switches, power sockets or light fittings shall be installed in
Fig-3
volumes 0 and 1. Above these volumes it shall be permissible to
have sound control contactors operated by a draw-cord or chain
of non-hygroscopic material.
Switches shall not be installed in volume 2, however safety
power sockets can be installed. Fixed light fittings may also be
installed, preferably with category II insulation or, if unavailable,
install those which do not have any accessible metallic part. In
the lamp holders it shall not be possible to make any accidental
contact with live parts when inserting or removing bulbs. In such
light fittings no switches or power sockets are allowed, except if
these are safety power sockets.
Volume 1
Volume 0
2. Wiring
The power cable used must be the one supplied with the bath or another of similar characteristics (with
the cover having characteristics not inferior to type H05 V V-F), taking into account the maximum voltage
2
stipulated in the low voltage regulations. The section of cable supplied is 1,5 mm .
The bath must be permanently connected to the electrical mains, with no extensions, and to the earth
installation. The use of a plug socket is not acceptable. Therefore, an electrical junction box must be
provided for connecting to the cable that supplies the bath. Said box will be of IPx5 type, fitted 20 cm
above the ground.
All interventions must be carried out by the personnel of the corresponding Technical Assistance Service.
If this cable is replaced, remember that the yellow-green earth wire must be at least 40 mm longer than
the live and neutral wires. This will ensure that if the cable is jerked, the last wire to disconnect will be the
earth wire, thus maintaining electrical protection at all times.

Publicidad

Tabla de contenido
loading

Tabla de contenido