Troubleshooting - Virax 294121 Manual De Instrucciones

Cable de 16m para mini visioval
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
3.5
Installing the 16 m CABLE for Mini VISIOVAL
Figure 3 shows the procedure for installing the portable Mini VISIOVAL camera in the space
provided on the 16 m CABLE for Mini VISIOVAL
16 m CABLE for Mini VISIOVAL
Figure 3
1.
Push and pull the cable steadily; do not use force in case of blockage. Avoid rubbing the
cable on sharp edges. Do not bend or twist the cable.
2.
Wipe the flexible cable clean with a dry cloth before inserting it in the compartment so as not
to soil the reel assembly.
4.
Cleaning instructions
1.
Remove the AA batteries from the base
2.
Use pads soaked in alcohol, soft detergent and water in order to remove any dirt and grease
from the product.
3.
Use a cotton cloth to clean the camera head
4.
Allow to dry before reinserting the AA batteries.
5.

Troubleshooting

Problem
The (mini VISIOVAL) camera
display does not turn on
The display turns on but does
not display the image
The display shows an image
which is frozen
Possible cause
The camera's battery is low
Ensure that the battery is
inserted in the battery
compartment of the mini
VISIOVAL.
Faulty electronic systems
Intermittent cable connection
The camera head is dirty
Error in the image processor
Mini VISIOVAL
Solution
Recharge the battery
Check for proper placement of
battery in the mini VISIOVAL
Contact the Virax After-sales
service
Check the cable connections
Clean the camera head
Turn the unit off and on to
reinitialise the processor