6.3

OPERATING MODES

CONDOMINIUM AUTOMATIC
The gate is opened when the START button is pressed whether the gate is closed or being closed. The START
command is ignored while the gate is being opened, whereas during the pause phase it makes the timing of this
phase restart. After pressing STOP, pressing START closes the gate.
SUPERAUTOMATIC
The gate is opened when the START button is pressed whether the gate is closed or being closed. While the gate is
being opened however it produces a STOP, after which a subsequent START closes the gate. During the pause
phase, pressing the START button closes the gate. After pressing STOP, pressing START closes the gate.
AUTOMATIC
The gate is opened when the START button is pressed whether the gate is closed or being closed. The START
command is ignored while the gate is being opened, whereas during the pause phase it makes the gate close again.
After pressing STOP, pressing START closes the gate.
SEMIAUTOMATIC
The START button controls the opening, closing and halting of the gate. After it is opened, it is necessary to press
the START button to close it again. While the gate is being opened, pressing START halts the gate and another
pulse makes the gate close. If START is pressed during the closing phase the direction is inverted. After pressing
STOP, pressing START closes the gate.
STEP BY STEP
The gate is opened when START pulse is pressed while the gate is closed.
The START command produces a STOP during the opening phase, subsequently pressing START causes the gate
to close, and pressing START again produces a STOP. After pressing STOP, pressing START closes the gate.
Select the operating mode using the 1,2,3 and 6 dip switches, with reference to the "OPERATING MODES SELECTION"
table (after each mode change it is necessary to short circuit JR1 reset contacts for a few seconds so that the change
can take effect).
Dip 1
Dip 2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
(1): The function comfort enables the gate to be closed 5 seconds after the photocells have received a pulse, regardless
of the timing of the pause setting.
(2): The function photocell retrigger makes the timing of the pause restart if the photocells are in use during the pause
itself.
6.4

SETTING

Through the 4, 5, 7 and 8 dip switches it is possible to configure certain functions of the equipment:
Dip switch
DS41035-001
OPERATING MODES SELECTION
Dip 3
Dip 6
OFF
OFF
Condominium automatic
ON
OFF
Condominium automatic + comfort (1)
OFF
OFF
Superautomatic
ON
OFF
Superautomatic + comfort (1)
OFF
OFF
Automatic
ON
OFF
Automatic + comfort (1)
OFF
OFF
Semiautomatic
ON
OFF
Step by step
OFF
ON
Condominium automatic + photocell retrigger (2)
OFF
ON
Superautomatic + photocell retrigger (2)
OFF
ON
Automatic + photocell retrigger (2)
Function
4
Preflashing
5
Release stroke
7
Flash light type
8
Closing stroke
Mode
ON
Enabled
Enabled
With board
Lamp only
Enabled
26
OFF
Disabled
Disabled
Disabled
LBT0197