Data transfer
The device features a Bluetooth
a Bluetooth
* interface (such as a smartphone or tablet).
®
The system prerequisites for a Bluetooth
The device can set up a Bluetooth
The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the
ambient conditions such as the thickness and composition of walls, sources of interference as well as
the transmit / receive properties of the terminal device.
Bluetooth
* must be activated after switching on the device as the measuring system or measuring
®
device is designed for very low power consumption.
A mobile device can link up to the active measuring device via an app.
Application (app)
An app is required to use the Bluetooth
You can download the app from the corresponding stores for the specific type of terminal device:
!
Make sure that the Bluetooth
After starting the app and activating the Bluetooth
a mobile device and the measuring device. If the app detects several active measuring devices, select
the matching device.
This measuring device can be connected automatically the next time it is switched on.
* The Bluetooth
word mark and the logo are registered trademarks of Bluetooth SIG Inc.
®
Technical data
(Subject to technical alterations. 18W09)
Function
AC current
50-60 Hz
DC current
AC voltage (Auto range)
* function that enables wireless data transfer to mobile devices with
®
* connection are specified at http://laserliner.com/info?an=ble
®
* connection with Bluetooth 4.0 compatible devices.
®
* function.
®
* interface of the mobile device is activated.
®
* function, a connection can be set up between
®
Range
Resolution
500.00 A
10 mA
1000.0 A
0.1 A
500.00 A
10 mA
1000.0 A
0.1 A
500.00 mV
0.01 mV
5.0000 V
0.1 mV
50.000 V
1 mV
500.00 V
10 mV
1000.0 V
0.1 V
ClampMeter XP
ClampMeter XP
Accuracy
% of measured value (rdg)
+ least significant digits
± (2,5% rdg ± 5 digits)
± (2,5% rdg ± 5 digits)
± (1,0% rdg ± 30 digits)
± (3,0% rdg ± 8 digits)
25