Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C) . • Nice S .p .A . reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality .
Model
Product Type
Useful conduit (m)
Maximum torque on start-up (Nm)
Nominal torque (Nm)
Manoeuvre time (sec adjustable)
Maximum operating cycle
frequency at nominal torque
(the control unit limits the work
cycles to the maximum set in table T3)
Durability
Power supply voltage
Power supply voltage /V1
Maximum power absorbed
on start-up (W)
Maximum power at nominal
torque (W)
Insulation class
Emergency power supply
Photovoltaic power supply
FLASH output
LIGHT output
SCA output
Output for flashing light/
traffic light on cover
BLUEBUS output
"STOP" input
"STEP-STEP" input
"OPEN" input
"CLOSE" input
Radio connector
Radio AERIAL input
Loop Detector Inputs
Nominal Loop inductance
Programmable functions
Functions in self-learning mode
Operating temperature
Protection rating
Dimensions (mm)
Weight
20 – English

TECHNICAL CHARACTERISTICS OF THE PRODUCT

M3BAR
Road barrier for residential use complete with electronic control unit
2,32 ÷ 2,82
100
30
1 .5 – 3
600
continuous use
230V 50/60Hz
120V 50/60Hz
150
40
1
for 1 LUCYB, MLB or MLBT flashing light signal (12V – 21W)
with optional accessories XBA7 led flashing light or XBA8 led traffic light
1 output with maximum load of 12 Bluebus units
For normally closed, normally open, 8 .2 kΩ constant resistance or OSE optical type contacts;
in self-learning mode (a change from the memorised state prompts the "STOP" command)
SM connector for receiver types SMXI, SMXIS, OXI or OXIT
8 ON-OFF functions and 8 adjustable functions (see tables 6 and 8) and additional programming
through the Programming Unit and Oview Command
Self-learning of devices connected to the BlueBus output . Self-learning of "STOP" type devices (contacts NO, NC
or 8 .2kΩ resistance) . Learning of pole opening and closing positions and calculation of the points of deceleration
and partial opening . Self-learning of the "Version"
-20°C . . . +55°C
IP54
400 x 299 x 1215 h
400 x 299 x 1215 h
80 kg
M5BAR
3,17 ÷ 4,82
200
70
3 – 6
350
continuous use
See chapter 3 - paragraph 3 .2 .1
230V 50/60Hz
230V 50/60Hz
120V 50/60Hz
120V 50/60Hz
110
50
1
Yes (with PS224 accessory)
Yes (with SYKCE accessory)
for optional accessory XBA4 "pole lights"
for signal indicator 24V (max 10W)
For Normally Open contacts
For Normally Open contacts
For Normally Open contacts
50 Ω for RG58 or similar type cable
2 per loop with a circumference from 2 to 16 m
100 to 400 μH
-20°C . . . +55°C
-20°C . . . +55°C
IP54
400 x 299 x 1215 h
80 kg
M7BAR
L9BAR
5 ÷ 7
7 ÷ 9
300
90
6 – 10
8 – 12
200
230V 50/60Hz
120V 50/60Hz
110
40
1
-20°C . . . +55°C
IP54
IP54
500 x 299 x 1215 h
85 kg
98 kg
400
130
150
160
50
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M5barM7barL9barLbar

Tabla de contenido