Possible Messages on Display
Fe
= Measurement on iron and steel substrates
NFe
= Non­Fe, a measurement on non­ferrous metallic substrates
Zero Reference Error = Zero setting error or incorrect use
INFI
= Measurements outside the measuring range, incorrect substrate
= Battery weak, have replacement batteries ready
= Battery weak or drained
= Automatic substrate changeover active

Technical Data

Device with dual probe:
Basic material (substrate)
Iron or steel
Non­magnetic metals, e.g.
aluminium, zinc, copper, brass
Measuring range
Resolution
Display
Measuring accuracy
Smallest measuring surface
Smallest radius
convex
concave
Smallest thickness
of base material
Temperature range
Storage
Operation
Probe
Power supply
Dimensions
Weight

Ordering Information

Paint Coating Thickness Meter with Dual Probe
Art. 0715 53 790
Fe probe
NFe­probe
Fe
0–3,000 µm
NFe
0–3,000 µm
Range 0–999 µm: 1 µm
Range ≥ 1 mm : 0.01 mm
Graphic display with background lighting
± (2 µm + 3 %*)
(*) of measured value
Fe
10 x 10 mm²
NFe
6 x 6 mm²
5 mm
25 mm
Fe
0.2 mm
NFe
0.05 mm
–10 °C to 60 °C
0 °C to 50 °C
Single­point
2 x batteries 1.5 V (AA alkaline, Art. 0827 02)
approx. 100 x 60 x 27 mm
approx. 105 g with batteries
P. Qty. 1