Connect the mains adapter with the energizer, as described in Fig. 3, via the
mains connection
. With the mains adapter it is easy to charge a connect-
2
ed 12 V rechargeable battery in parallel operation.
If the 230 V/110V supply fails, the energizer is then supplied from the re-
chargeable battery.
Installation with 230V/110V:
Insert the energizer's mains plug into the power socket.
CAUTION!
The energizer has an AUTO-ON function. As such, the energizer
starts following connection to the mains network.
3. Commissioning
Commissioning - Power supply units:
Device starts automatically once it is connected to the power supply After 1
second, you will hear a rhythmic even ticking of the pulses; the device is in
operation.
The energizer transmits pulses to the fence and the LED display lights up.
The fact of the status LEDs not lighting up points to a defect in the power
supply
4. Energizer Operating Description
Rechargeable battery indicator:
The rechargeable battery indicator provides information about the rechargeable battery or battery voltage.
Power economiser:
A fitted power economiser matches power consumption to the state of the fence. This means less current consumption with
well insulated fences and a greater current consumption with poorly insulated fences (leakages due to plant growth, etc.).
5. Maintenance
Table 13 (12V rechargeable battery)
Remaining capacity
Flashing light
green
red/
20-40%
Flashing light
green
Flashing light
red
0-20%
The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge capacity left) to
prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
4
Rechargeable battery good
40-100%
Charge the battery
Rechargeable battery absolute-
ly depleted
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied - cover panel )
6. Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
● Switch off energizer
● Disconnect entire energy supply from the energizer.
● Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compati-
ble manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety &
environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
7. Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
Table 14
Faults
Display
Rechargeable battery under
LED flashes alternately red/green
40% capacity
Rechargeable battery under
LED flashes red
20% capacity
farmer AN100_ farmer AN200_ farmer AN300
Corrective action
Charge the battery
Charge the battery
5