10
www.electrolux.com
Problem
Water leaks
No hot water
Insufficient hot water
High operation cost (power
consumption)
Dripping from safety valve
Brown (rusty) water from
outlet
10. TECHNICAL DATA
10.1 Details on energy
consumption
Product data complies with EU
regulations relating to the Directive on
Possible causes
Improperly sealed, hot or
cold water source connec‐
tions.
No power to heater.
Cold water mix fast with
appliance stored hot water,
high water source pres‐
sure.
Wrong piping connections. Correct piping.
Wasted hot water.
Long runs of exposed pipe. Insulate piping.
Hot water piping on out‐
side wall.
Wrong piping connections. Correct piping.
Wasted hot water.
Long runs of exposed pipe. Insulate piping.
Hot water piping on out‐
side wall.
Leaking Taps.
High water source pres‐
sure.
Brown or rusty water indi‐
cates a worn out anode
rod
the ecodesign of energy related products
(ErP).
Solution
Tighten threaded connec‐
tions.
Turn on electrical switch,
Check for blown fuses or
tripped breaker.
Close the inlet water serv‐
ice valve(or the pressure
regulator) partially until the
problem disappear.
Review and reduce hot
water consumption.
Insulate piping.
Review and reduce hot
water consumption.
Insulate piping.
Repair leaking taps.
Install a 3 or 4 bar pres‐
sure regulator valve in the
mains connection of the
house.
Call authorized professio‐
nals for anode rod exami‐
nation and replace it if nec‐
essary