Checking Connections; Trimmer Functions - Beninca KER EU Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
1) Cut off power supply.
2) Manually release the door, move it at around half stroke and lock it again.
3) Reset power supply.
4) Send the step-by-step (P.P.) control signal through the P2 key, P.P. or remote control.
5) The door leaves should open. If not, with stopped motor, it is sufficient to invert the move wires
of the motor (MOT/MOT) of the motor and the limit switches (SWO/SWC).
6) Adjust Times and operating Logics.
TW
It allows the maximum duration of opening and closing.
It must be preset approx. 4s more with respect to the actual stroke time of the
system.
The adjustment ranges from 3s to 180s maximum.
TCA
It allows to adjust the automatic closure time.
The adjustment ranges from 3s to 180s maximum.
With TCA trimmer completely turned clockwise, the DL2 LED (green) switches off, TCA
is deactivated.
Dip-Switches
Function
DIP1
Torque and pre-
warning light
DIP2
Multi-flat
DIP3
PHOT: operating
mode
DIP4
P.P.: operating
mode
DIP5
Rapid closure
DIP6
Radio

CHECKING CONNECTIONS:

TRIMMER FUNCTIONS

DIP-SWITCH FUNCTION
Description
To be used only to programme the torque and the pre-
warning flashing, as shown hereunder. Once the parame-
ters are preset, move back to OFF.
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function.
The P.P. (Step-by-step) impulse or the impulse of the
transmitter have no effect in the opening phase.
The operating mode of the PGOT input is selected
Off: Input, activated in both opening and closing phases
On: Input, activated in the closing phase only
The operating mode of the "P.P. push-button" and the
transmitter are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation: OPEN > CLOSE > OPEN >
The rapid closure is enabled or disabled with (only with
activated TCA)
Off: disabled rapid closure
On: enabled rapid closure. The triggering of the photocell
involves, after approx. 3s, the closure of the door.
The programmable code transmitters are enabled or
disabled.
On: Radio receiver is enabled for roll-on code transmitters
only.
Off: Receiver is enabled for both roll-on and programma-
ble code transmitters.
9

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido