SATA spray master RP Instrucciones De Servicio página 126

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 137
Operating Instructions SATA spray master RP
EN
■ Open bleeder valve [1-2] briefly and check whether the pressure gauge
adjusts back to the required pressure again.
Adjust gun inner pressure
Notice!
When using an external pressure regulator to adjust the gun inner pres-
sure, the air micrometer [# 53603] must be wide open (vertical posi-
tion).
Notice!
The most precise way to adjust the gun inner pressure is with SATA
adam 2.
Notice!
If the gun input pressure does not reach the necessary level, increase
the pressure in the compressed air circuit.
Too much input pressure results in high trigger forces.
■ Pull trigger guard [1-12] right back.
■ Proceed with adjustment using one of the following possibilities. Note
the maximum gun inlet pressure (see chapter 7).
■ Adjustment with SATA adam 2.
■ Adjustment with external pressure regulator.
■ Bring the trigger guard to the starting position.
Adjust the material flow
Notice!
Wear at the fluid tip and paint needle is lowest when the material flow
control is wide open. Select fluid tip size according to the material and
working speed.
Fully variable adjustment of the material flow and thus the needle stroke
is possible with the adjusting screw [1-4].
■ Loosen counter nut.
■ Pull trigger guard [1-12] right back.
■ Adjust material flow at the adjusting screw [1-4].
■ Tighten counter nut by hand.