Troubleshooting; Corrective Action - SATA spray master RP Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 137
SATA spray master RPOperating Instructions
US
Notice!
Risk of material damage from improper cleaning tools
Never clean soiled bore holes with improper objects. Even the slighted
damage can affect the spray pattern.
→ Use SATA nozzle cleaning needles (# 62174) or (# 9894).
Information!
In rare instances, some parts of the paint spray gun may have to be re-
moved to clean it thoroughly. If disassembly is required, limit this only to
the parts that come in contact with material as a result of their function.
■ Flush the paint spray gun well with a thinner.
■ Clean air nozzle with a paintbrush or brush.
■ Lightly grease moving parts with gun grease.

11. Troubleshooting

Only trained experts are permitted to rectify the malfunctions described
below.
If it is not possible to rectify a malfunction using the remedies described
below, send the paint spray gun in to the SATA Service Department (see
Chap. 16 for address).
Malfunction
Uneven spray jet (pul-
sating/sputtering) or
air bubbles in gravity
flow cup.
Spray pattern too
small, slanted,
one-sided or split.
Round/flat fan control
cannot be turned.
512
Cause
Paint nozzle not se-
cured tightly.
Bore holes in air noz-
zle clogged with paint.
Paint nozzle tip (paint
nozzle in) damaged.
Round/flat fan control
turned too sharply
counterclockwise;
spindle loose in gun
threading.

Corrective action

Tighten paint nozzle
using universal wrench.
Clean air nozzle. Read
and follow cleaning
instructions (see 10).
Check fluid tip pin for
damage and replace
nozzle set if necessary.
Unscrew and remove
control using a sin-
gle-ended open-jaw
wrench; repair or re-
place completely.

Publicidad

Tabla de contenido
loading