Operating Instructions SATAjet 3000 K (RP/HVLP)
Description
Weight
8. Operation
Warning!
Risk of injury from bursting compressed air hose
If an unsuitable compressed air hose is use, it can be damaged by too
much pressure and explode.
→ Only use solvent-resistant, antistatic and technically flawless hose for
compressed air with permanent pressure resistance of 10 bar, bleeder
resistance of < 1 MOhm and min. inner diameter of 9 mm (see chap-
ter 14).
Warning!
Risk of injury from excessive material input pressure
Excessive material input pressure can cause bursting of the material
hose and other components conveying material.
→ The material input pressure stated on the gun may not be exceeded.
Attention!
Damage from dirty compressed air
Using soiled compressed air can cause malfunctions
.
→ Use clean compressed air. For example with SATA filter 100
(# 148247) outside the spray booth or SATA filter 484 (# 92320) inside
the spray booth.
Before using the spray gun, heed / check the following points to warrant
safe working:
■ Screws [2-1], [2-2], [2-3], [2-4] and [2-5] fit firmly. Tighten screws if
necessary.
■ Fluid tip [2-2] tightened with a torque of 14 Nm [7-5].
■ Locking screw [10-1] tightened.
■ Technically clean compressed air is being used.
8.1. First Use
■ Always blow through compressed air pipe before installation and rinse
through material pipe.
RP
EN
HVLP
570 g
127