Initial Operation - SATA SATAjet 1000 B Instrucciones De Servicio

Ocultar thumbs Ver también para SATAjet 1000 B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 133
SATAjet 1000 B (RP/HVLP) Operating Instructions
US

7.1. Initial Operation

■ Purge compressed-air line thoroughly prior to assembly.
■ Flush paint passage with suitable cleaning agent [2-6].
■ Screw connecting nipple [2-10] onto air connection [1-8].
■ Adjust air nozzle.
Horizontal spray [2-8]
Vertical spray [2-7]
■ Attach paint strainer [2-12] and gravity flow cup [2-13].
7.2. Normal Operation
Connecting the paint spray gun
■ Connect the compressed air hose [2-11].
Adding material
Information!
When painting use only the quantity of material required for the work
step.
Maintain the necessary spray distance when painting. Store or dispose
of the material properly after painting.
■ Remove screw-on lid [2-14] of gravity flow cup [2-13].
■ Press anti-drip device [2-9] into screw-on lid.
■ Fill gravity flow cup (max. 20 mm below upper rim).
■ Screw screw-on lid onto gravity flow cup.
Adjusting the spray gun internal pressure
Information!
For adjustment options [3-2], [3-3] and [3-4] the air micrometer [1-5]
must be fully open (vertical position).
Information!
For the best accuracy, the spray gun internal pressure can be set using
the SATA adam 2 [3-1].