Troubleshooting Guide - Technibel MCW Instrucciones De Uso

Unidades terminal
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ACTIVATED CARBON AIR FILTER
• The filter is to be mounted in addition to the normal filter.
• It is made of two layers:
- the first layer consist in a synthetic honey comb high efficiency media to remove the dust and purifing the air,
- the second layer in coarcoal media deodorizing the ambient air.
Fitting the activated carbon air filter.
• MCW
1 - Open the air intake grille and remove the 2 filters supplied
with the unit.
2 - Fit the 2 activated carbon filters into position as shown in
the illustration ("FRONT" in front).
3 - Replace the 2 filters in their housing and close the grille.
• KPSW
1 - Open the unit intake air grille and pull out the standard air
filter.
2 - Apply on the rear side of anti-mold filter the two springs
supplied with the accessory.
3 - Fix the "air clean" filter by the springs.
4 - Insert the two air filters one over the other and close the
intake grille.
9 - ADVICE ON COMFORT AND ENERGY SAVING
AVOID:
• Blocking the appliance's air inlet and outlet grilles. If they are
blocked, the appliance will not work satisfactorily and it may
be damaged.
• Allowing the sun to shine directly into the room when the
appliance is operating in "air conditioning" mode. Use
shutters or curtains.

10 - TROUBLESHOOTING GUIDE

• If the air conditioner is not working properly, carry out the following checks before calling the After-Sales Department.
• If the problem persists, contact the After-Sales Department.
PROBLEMS
The air conditioner is not operating at
all (the fan never comes on).
Insufficient cooling or heating.
For installations which can operate in
cooling or heating mode:
excessive or non-existent cooling or
heating.
(accessory supplied on request)
KPSW
CHECK:
• That the filter is always clean. A clogged filter will reduce the
appliance's efficiency.
• That all doors, windows and other openings are closed in
order to prevent non-cooled air entering when the appliance
is operating in the "cooling" mode.
POSSIBLE CAUSES
1 - Power cut.
2 - Circuit-breaker thrown or fuse blown.
3 - Line voltage too low.
4 - The selector switch is on "0" (off).
5 - The setpoint temperature is set too high
for cooling or too low for heating.
1 - Air filter dirty or blocked.
2 - Heat source or too many people in the
room.
3 - Doors and/or windows open.
4 - Obstacle in front of the air inlet or outlet.
5 - The setpoint temperature is set too high
for cooling or too low for heating.
6 - The installation's cold water or hot water
generator is operating incorrectly or not
operating at all.
1 - The thermostat operating mode (heating
or cooling) is not adapted.
2 - The installation's cold water or hot water
generator is operating incorrectly.
MCW
Activated carbon air filter
"Air clean" filter
(high efficiency honeycomb
and coarcoal media)
1 - Restore the supply.
2 - Contact the After-Sales Department.
3 - Consult your electrician.
4 - Work the selector switch.
5 - Set the temperature lower (or higher).
1 - Clean the air filter.
2 - If possible, eliminate the heat source.
3 - Close them to prevent outside air
entering.
4 - Remove the obstacle in order to provide
good air circulation.
5 - Set the temperature lower (or higher).
6 - Check the operation of the generator.
Contact the After-Sales Department.
1 - Check the mode selected.
2 - Check the operation of the generator.
Contact the After-Sales Department.
Rear side of
anti-mold filter
Spring
SOLUTIONS
5
F
GB
I
E
D

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kpsw

Tabla de contenido