English
NOTICE: If the overload protector stops the pump repeatedly, dis-
connect the power from the pump and check it to find the problem.
Low voltage, long extension cords, clogged impeller, too much
back pressure in the discharge hose (as when pumping through
50' (15 M) of coiled hose), or running pump with no load, can all
cause excessive cycling and overheating.
5. For Model FP0S1300X, the water being pumped cools the motor,
allowing the pump to run continuously at any depth of water above
3/16". However, if the motor overload stops the pump, allow it to
cool for one hour before restarting. Motor will not restart before
the overload has cooled.
6. For Models FP0S1100X and FP0S1250X, do not try to run the
pump continuously when the water level is below 4" (102mm) or
about 1/3 of the way up the motor casing, as it will overheat. If the
motor overheats and the overload stops the pump, allow it to cool
Models
FP0S1300X-08
FP0S1600X-08
Anti-Airlock
Orient Part Number with
Hole
Anti-Airlock Hole as shown
Tighten 1st
2nd
3rd
Install shield and tighten
screws in sequence as shown.
Key
Part Description
1
Screen
2
Shield
3
Impeller - S1300X
3
Impeller - S1600X
4
Motor
5
Power Cord
•
Garden Hose Adapter
** If motor fails, replace entire pump.
• Not Illustrated.
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE(S)
Pump won't
Blown fuse
start or run
Low line voltage
Defective motor
Impeller
Pump operates but
Low line voltage
delivers little or
no water
Something caught in impeller
Small diameter garden hose
or long discharge line
Check valve installed without
vent hole
Air lock
Coils or bends in hose
For parts or assistance, call Flotec Customer Service at
Anti-Airlock
Hole
Qty.
Part No.
1
PS8-5P
1
PS70-3P
1
PS5-24P
1
PS5-25P
1
**
1
PS117-54-TSU
1
FT0013-43
CORRECTIVE ACTION
If blown, replace with fuse of proper size
If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company.
Replace pump
If impeller won't turn, for models FP0S1100X and FP0S1250X,
remove housing; for model FP0S1300X, remove screen.
Locate source of binding
Use only 14 gauge or larger extension cords. Use short extension cords
when necessary
Clean out impeller
Use larger diameter garden hose or 1" flexible pipe. Eliminate any
excess hose. Short hoses work best
Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump
discharge & check valve
Turn off pump for a few seconds, clean out anti-airlock hole and restart pump
Straighten hose
for one hour before restarting. Motor will not restart before the
overload has cooled.
AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock
will cause the pump to overheat and fail. This pump has an anti-airlock
hole in the bottom of the pump body. If you suspect an airlock, unplug
the pump, clean out the anti-airlock hole with a paper clip or piece of
wire, and restart the pump.
IMPORTANT: This hole allows the pump to start priming within 15 sec-
onds in as little as 1/2" of water. NEVER restart pump in less than 1/2"
of water. Leakage from the anti-airlock hole is normal.
* Lake Chemical Co., Chicago, Illinois
5
4
3
2
1
5125 0905
Key
Part Description
1
Lower Base Plate
2
Impeller (FP0S1100X)
2
Impeller (FP0S1250X)
3
Volute Gasket
4
Upper Base Plate
5
Motor
6
Power Cord
•
Garden Hose Adapter
** If motor fails, replace entire pump.
• Not Illustrated.
Models
FP0S1100X
6
FP0S1250X-08
5
4
3
2
1
Qty.
Part No.
1
FP0005797A
1
PS5-24PA
1
PS5-24P
1
U9-406
1
FP0005796A
1
**
1
PS117-54-TSU
1
FT0013-43
1-800-365-6832
3