Install Software and Documentation
To configure an In-Sight vision sensor, In-Sight Explorer software must be installed
on a networked PC. In-Sight software is available as a free download from the In-
Sight support site: cognex.com/support/insight.
Log On to the Vision Sensor
1. Open the In-Sight Explorer software.
2. From the Get Connected Application Step, select your In-Sight vision
sensor from the Select an In-Sight Sensor or Emulator group box and click
Connect.
In-Sight 2000 Vision Sensor Specifications
Specifications
2000-110
Operating: 0°C to 40°C (32°F to 104°F)
Temperature
Storage: -10°C to 60°C (14°F to 140°F)
Maximum
< 95%, non-condensing
Humidity
Protection
IP65 when all connectors are attached to cables or shielded by a sealing cap
Shock (Shipping
IEC 60068-2-27: 1000 shocks, semi-sinusoidal, 11g, 10ms
and Storage)
Vibration
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz
(Shipping and
at 100m/s2 /15mm)
Storage)
2000-
2000-
120/120C
130/130C
12
2000-
2000-23M
230/230C
2001-
230/230C