D902 Vision System Specifications

Specifications
Power
24VDC ±10%, 1.5A maximum.
Consumption
Power Output
24VDC @ 750mA maximum to external light.
Case
0°C to 65°C (32°F to 149°F)
1
Temperature
Storage
-20°C to 80°C (-4°F to 176°F)
Temperature
Humidity
< 80% non-condensing
Protection
IP67 with all cables properly attached (or the provided connector plug installed), the IP67-rated
cover properly installed, and the Micro SD card cover fastened in place.
Shock
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s
(Shipping and
11ms, half-sinusoidal) with cables or cable plugs and a 150 gram or lighter lens attached.
Storage)
Vibration
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz at
(Shipping and
100m/s
2
Storage)
1
To verify case temperature, use the GetTemperature spreadsheet function, which returns the vision system case
temperature in degrees Celsius. For more information, see the In-Sight
be used to determine the vision system case temperature. Additional cooling measures are required if the case
temperature cannot be kept below 65°C. Examples of such measures include: extra heat sinking and/or air
movement.
2
Before you ship this product or any machinery that contains it, remove lenses that weigh more than 150 grams.
D902
Note: This product can have repetitive surges with high peak currents. A power source
rated for at least 5A continuous current is required to supply these surges and prevent the
product from operating unreliably.
2
/ 15mm) with cables or cable plugs and a 150 gram or lighter lens attached.
®