Cognex In-Sight 7000 Gen2 Serie Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 151
7600 Series Vision System Specifications
Specifications
Power Consumption
Power Output
1
Case Temperature
Storage Temperature
Humidity
Protection
Shock (Shipping and Storage)
Vibration (Shipping and Storage)
1
To verify case temperature, use the EV GetSystemConfig("Internal.Temperature") Extended Native Mode
command or GetSystemConfig("Internal.Temperature") spreadsheet function. When issued, it returns the vision
system internal temperature in degrees Celsius, which is approximately 3 to 5 degrees above the vision system
case temperature. For more information, see the In-Sight
determine the vision system case temperature. Additional cooling measures are required if the case temperature
cannot be kept below 50°C. Examples of such measures include: extra heat sinking and/or air movement.
2
Before you ship this product or any machinery that contains it, remove lenses that weigh more than 150 grams.
7600
24VDC ±10%, 1.5A maximum.
24VDC @ 750mA maximum to external light.
0°C to 50°C (32°F to 122°F)
-20°C to 80°C (-4°F to 176°F)
< 80% non-condensing
IP67 with all cables properly attached (or the provided connector plug
installed), the IP67-rated cover properly installed, and the Micro SD card
cover fastened in place.
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z)
axis) 80 Gs (800m/s
and a 150 gram or lighter lens attached.
2
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @
10 Gs (10 to 500 Hz at 100m/s
150 gram or lighter lens attached.
®
Explorer Help file. A thermal scanner can also be used to
20
2
at 11ms, half-sinusoidal) with cables or cable plugs
2
/ 15mm) with cables or cable plugs and a
7600C

Publicidad

Tabla de contenido
loading

Tabla de contenido