Table of adjustments for Exclusive Green E 35 C.S.I. - R.S.I.
Maximum
Pipes Ø 50
number of
maximum
fan rotations
length
(rpm)
DHW
CH
m
6.000
5.300
1
6.100
5.400
2 (*)
6.200
5.500
5
6.300
5.600
8
(*) Length that can be installed with pipes in class P1
NOTE
If pipes other than those in the Beretta catalogue are used, refer to the
ΔP values in the tables above to calculate the maximum length of the
pipes.
The Ø 60, Ø 50 and Ø 80 configurations use test data obtained in the
laboratory.
In the event of installations that differ from the indications in the "stand-
ard configurations" and "adjustments" tables, refer to the equivalent
linear lengths below.
10
Pipes Ø 60
Pipes Ø 80
ΔP at boiler
maximum
maximum
length
length
max. length
m
m
12
66
15 (*)
83 (*)
126
168
curve 90° Ø 80 mm
bend 90°, diameter 80mm
4.5m, diameter
4,5 m Ø 80 mm
80mm
b
In any case, the maximum lengths declared in the instructions are
guaranteed, and it is essential not to exceed them.
COMPONENT Ø 60
output with
45° bend Ø 60
90° bend Ø 60
Pa
Extension 0.5m Ø 60
170
Extension 1.0m Ø 60
197
Extension 2.0m Ø 60
265
330
COMPONENT Ø 50
45° bend Ø 50
90° bend Ø 50
Extension 0.5m Ø 50
Extension 1.0m Ø 50
Extension 2.0m Ø 50
camino per intubamento Ø 60 o Ø 50
4.5m, diameter
4,5 m Ø 80 mm
80mm
riduzione Ø 80-60 mm
Reduction diameter
o Ø 80-50 mm
80-60mm or 80-50mm
Linear equivalent in metres Ø 80 (m)
Linear equivalent in metres Ø 80 (m)
Stack for pipes diameter
50mm, 60mm or 80mm
curva 90° Ø 60 mm,
bend 90°, diameter 60mm,
Ø 50 mm o Ø 80 mm
50mm or 80mm
5
8
2,5
5,5
12
12,3
19,6
6,1
13,5
29,5