EXCLUSIVE GREEN E C.S.I. - R.S.I.
13 - START-UP AND OPERATION (EXCLUSIVE GREEN E R.S.I.)
This boiler is able to operate in different conditions:
CASE A - only heating
CASE B - only heating with external water tank connected, managed by a thermostat, to prepare domestic hot water
CASE C - only heating with external water tank connected, managed by a temperature sensor (kit available upon request), to prepare domestic
hot water.
Depending on the type of installation selected, it is necessary to set the parameter "domestic hot water mode". This operation must be performed
by a Technical Service Centre when starting-up the boiler.
Description of commands
Heating water circuit
temperature selector
ON-OFF-RESET
function selector
Operating mode button
Heating water temperature selector: sets the heating water
temperature.
DHW temperature selector (C case): sets the domestic hot water
temperature storaged in the water tank.
Setting parameters selector (cases A, B and C): using in calibration
and programmation phase.
Function key:
- ON
the boiler is electrically powered and waiting for operating
requests (
-
- OFF
the boiler is electrically powered but will not respond to operating
requests
- RESET resets the boiler following a fault
Operating mode button:
operating mode: pressing it, the indicator "function selector"
to:
(winter) or
(summer, only if water-tank connected).
Info button: shows a sequence of information concerning the operating
status of the machine.
Switching on
b
The first time you turn the boiler on and in case of maintenance
work, before using the appliance you must fill the siphon with
water and make sure that the condensation is evacuated correctly.
Fill the condensation collection siphon pouring 1 litre of water into
the boiler combustion-analysis outlet with the boiler off, and check
that:
- the safety cut-off device is floating
- water is flowing correctly from the discharge pipe out of the
boiler
- the condensate outlet connection line is watertight.
If the condensate outlet circuit (siphon and pipes) is working correctly,
the condensation level will not exceed the maximum.
Filling the siphon before using the appliance, and the use of a safety
cut-off device inside the siphon, prevent exhaust gases from being
released into the environment.
Repeat during standard and non-standard maintenance work.
20
INFO
button
DHW
temperature
selector
Setting parameters
)
button allows to choose the desired
Description of display symbols
graduated heating water temperature scale with heating function
symbol
graduated domestic hot water temperature scale (shown in C case
only)
domestic hot water function symbol (shown in B and C cases)
fault symbol
reset symbol
selector
pressure value
external sensor connection
heating/domestic hot water temperature (shown in C case only)
or
fault symbol (e.g. 10 - no flame)
function selector (turned to the chosen operating mode:
or
summer (only if water-tank connected)
burner operating symbol
anti-freeze function active symbol
moves
Fig. 4.1
winter
MAX