TESTING OF THE APPLIANCE
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
that of the appliance.
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment,
activate all the safety devices provided and
decide whether staff at work and those in
the vicinity should be informed. In particu-
lar, turn off the water supply tap, cut off the
IT
GB
DE
ADJUSTING THE WELL LIMIT STOP MICROSWITCH
Important
FR
This adjustment must be made with the well
completely lowered.
ES
To carry out this operation, proceed as follows.
1 - Remove the knob (B).
NL
2 - Undo the screws (C) and remove the control
panel (D).
English
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
ADJUSTMENTS
electricity supply using the master switch
and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
- 20 -
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Check that the safety device is operating cor-
rectly.
C
B
8
D
C
IDM-39616301500.tif