REPLACING THE WELL TILTING DEVICE
To carry out this operation, proceed as follows.
1 - Remove the knob (B).
2 - Undo the screws (C) and remove the control
panel (D).
3 - Undo the nut (E).
4 - Undo the screws (F) and remove the bushes
(G).
5 - Unscrew and replace the threaded rod
(H).
6 - Set the bush (L) at the distance as shown
in the figure.
7 - Reassemble the bushes (G) and tighten the
screws (F).
8 - Fully tighten the nut (E).
IT
Important
Lubricate the threaded rod (H) with Teflon
grease (Tecnolube Seal RHEOLUBE 368F,
GB
OKS 265, etc.).
9 - Replace the control panel (D) and the knob (B)
DE
on completion of the operation.
FR
DECOMMISSIONING THE APPLIANCE
ES
Important
NL
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-
ments.
English
B
F
H
G
E
- 22 -
C
D
C