Abbreviations And Measurements En - Abicor Binzel iROB Feed 22/MP Instructivo De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

iROB Feed
Supply voltage
Rated power
Rated current (100 % duty cycle)
Max. welding current at 80% duty cycle
Wire drive
Wire feed rate
Torque
Cable assembly connection
Dimensions (lxwxh)
Weight
Speed control
Shielding gas max. pressure
Blast air max. pressure
Wire Brake max. pressure (option)
Tab. 1
Technical data iROB Feed 22/MP
Fe - Mild steel
Ss - Stainless steel
Al - Aluminium
Filler wire
Protection type
Standards
Tab. 2
Wire diameter iROB Feed 22/MP
Ambient temperature
Relative humidity
Tab. 3
Storage in an enclosed room, ambient temperature
Ambient temperature for transport
Relative humidity
Tab. 4
3.2 Abbreviations and measurements
CAN-BUS
GND
Tab. 5
Units of measurements in drawings or diagrams
Tab. 6
BAL.0331.0 • 2019-03-11
22
48 VDC
130 W
max. 4.5 A
500 A
4 rolls (ø 37 mm)
0.5 - 22 m/min
≠ 4 Nm
Euro-ZA or RPC
332 x 198 x 188 mm
6.4 kg
Encoder
max. 0.7 MPa (7 bar)
0.10 MPa (10 bar)
0.3 MPa (3 bar)
22
0.8 - 1.6 mm
0.8 - 1.6 mm
0.8 - 1.6 mm
1.2 - 2.4 mm
IP23S
EN 60974-5 / EN 60974-10
Ambient conditions for operation
Ambient conditions for shipment and storage
Controller Area Network Binary Unit System
Ground
Abreviations
Dimensions
3 Product description
MP
Depending on the torch
drive Ex. MF1
48 VDC
max. 4.5 A
500 A
4 rolls (ø 20 mm)
0.5 - 22 m/min
≠ 4 Nm
ABIPLUG
251 x 185 x 172 mm
3.5 kg
Encoder
max. 0.7 MPa (7 bar)
0.10 MPa (10 bar)
MP
0.8 - 1.6 mm
0.8 - 1.6 mm
0.8 - 1.6 mm
-
IP23S
EN 60974-5 / EN 60974-10
- 10 °C to + 40 °C
up to 90 % at 20 °C
- 25 °C to + 55 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
Millimetres [mm]
32 VDC
90 W
Encoder
EN - 7

Publicidad

Tabla de contenido
loading

Tabla de contenido