GETTING STARTED

ELECTRIC SHOCK:
Before filling the pump, or before any maintenance operation,
unplug the pump from the mains.
Install the pump in a place protected from rain and floodings, with
sufficient air flow
Pump has to be installed between the skimmer and the filter of the swimming
pool. The filter cap must be reachable easily, in order to ease filter cleaning
- Fix the pump in horizontal position, close from water, in order minimize suction
distance, and to reduce head losses
- It is recommended not to install the pump more than 1 meter above he water
level, in order to ease priming process and pump functioning
- Fill pump housinf with water (use opening 4 or 5), untill the pump is full
- Screw suction connector (4) and delivery connector (5)
- Connect the pump to the hoses of the swimming pool system:
• If you have threaded connectors on your system that are compatible with
the pump, use PTFE to ensure airtightness of the connection
• If not, make the connection by sticking the hoses of your system with
pump connectors.
- Open the gates of the system and plug the pump to the mains
- Pump priming may take a few minutes.
Hoses of the system must be fixed in order to avoid mechanical
constraints on the pump
Suction hoses must be installed with regular slope, in order to avoid
u-bend and air pockets.