5.
Position cap fl at on the vessel housing.
IMPORTANT
Make sure the o-ring is secure in the groove on the vessel top, not on the underside of the
cap. Turn large collar clockwise until it locks into place, do not over tighten.
6.
Open any valves that were closed to isolate the Nature
6.5 Winterizing
Make sure to wear gloves, eye protection, and protect any exposed skin when removing chlorine tablets. Review
the safety and fi rst aid information provided with all chemicals before using.
Consult your dealer for complete information on pool care and maintenance in cooler temperatures.
In cold climates, where the pool is closed:
2
1.
Remove the Nature
the collar.
2.
Review chemical use hazard on page three (3) of this manual before opening the chlorine chamber. Carefully
remove any remaining chlorine tablets.
3.
Replace empty chlorine holder into unit, retighten collar and run pump for 30 minutes.
4.
Remove and save the drain plug.
5.
Rinse out Nature
2
Fusion thoroughly with water.
6.
If blowing lines clear with air, set chlorine regulator dial to 5.
7.
After completing winterization, loosen collars.
6.6 Spring Start Up
1.
Replace the drain plug.
2.
Start up your pool as normal.
3.
After the water has been balanced, insert the new Nature
precautions), and complete the cartridge start up procedures in the Nature
Nature
2®
Fusion Inground Installation and Operation Manual
cartridge and discard with household trash. Put the temporary cap on unit and tighten down
2
Fusion.
CAUTION
cartridge, add the chlorine tablets (see Section 5.3 for
2
2
cartridge owner's manual.
Page 17