duction section for the detail operation, the load-
ed state will show in the middle box. Touch Flat EQ
to eliminate EQ settings and restore it to default.
In this area, you can touch the grid area to enter
EQ page, for the detail of EQ function, please refer
to the EQ introduction in section "PEQ interface".
Touch the switch to enable Compressor
function, then rotate Parameter Adjust
knob or slide long fader on the right
LCD screen to adjust value of Thresh-
old, which will show in the middle box.
During adjustment, corresponding
figure change will show in the Compres-
sor grid. In this area, you can touch the
grid area to enter COMP page.
Touch anyone of these controls to enter corre-
sponding page.
It is the same with that in Assign inter-
face in section "Assign interface".
Note: you can also rename the selected channel
by long pressing CHXX.
Gate interface
Touch the switch in this window, you
can engage and disengage the Gate for
the selected channel. It will illuminate to
indicate that the Gate has been touched and en-
abled. The LCD display shows the Gate setting in
real time. Its parameters can change by adjusting
Threshold, Attack & Release control directly and
use the Parameter Adjust knob to set the value.
P. 22
AUDIOLAB Live 24 XL -
English version
will illuminate and synchro-
nize with ON/OFF control in
EQ page. Please set values
in EQ page because it is not
adjustable here. This page
can only show the values.
You can also load a preset,
please refer to load intro-
Please notice that only if the Gate control has
been enabled can its parameters be adjusted.
It will lights Green when the switch is
ON, there is signal input and the value
is below threshold level, which means it enables
the gate function.
Touch it to set the level at which the
gate will open. It can be set from 20 to
-84 dB.
Touch it to set the time for the gate to
change from closed to open, much like
a fade-in. It can be set from 0.5 to 200 ms.
Touch it to set the amount of time for
the gate to go from open to fully close.
It can be set from 0.01 to 1 second.
Note: A fast release abruptly cuts off the sound
once it has fallen below the threshold, A slower
release smoothly changes from open to closed,
much like a slow fade out. If the release time is
too short a click can be heard when the gate re-
opens.
The Gate grid shows level
setting of threshold in real
time. Meter on the left indi-
cates the input signal's level
activity.