Make Electrical Connection
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MODELS EVL43
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install
a UL listed or CSA approved ½" strain relief.
4. Run home power supply cable through strain relief, into
terminal box.
E
D
C
B
A
A. UL listed wire connectors
B.White wires
C. Black wires
D. Green (or bare) wire connected to
yellow-green wires
E. Home power supply
5. Use UL listed wire connectors and connect black wires
(C) together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING: Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
MODELS EPT43 & ETB43
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
A. Knockout
B. Terminal box cover
4. Run home power supply cable through strain relief, into
terminal box.
A
C
D
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
5. Use UL listed wire connectors and connect black wires
(C) together.
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING: Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box. Failure to do so can result in death or
electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
10
⁄
" strain relief.
1
2
B
E
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires