Installation
4.3.2
Optional swing attachment
The optional swing attachment is clamped to the housing. The swing attachment
must be fastened to the housing in the area of the piston tube only (see Fig. 1
„Components of the device").
When installing it, note that the pins are aligned in line with the piston end at-
tachment.
The swing attachment can be spread slightly to simplify adjustment on the
housing by screwing in a screw into the centre thread. This screw must be sla-
ckened off before tightening the clamping screws and must not be under pres-
sure.
The clamping screws must be tightened alternately. Repeat this procedure until
the tightening torque of 6 Nm has been reached with both screws.
Clamping the swing attachment to the device may result in pressure marks on
the surface of the piston tube.
Fig. 2
The swing attachment can be ordered as part number 754068901.
20
Swing attachment