Warnings And Cautions - Gima 30940 Manual De Uso Y Mantenimiento

Casco led
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
5
Thank you for purchasing this product. To prevent damage to your product or injury to yourself or to
others, read the following safety precaution in their entirety before using this equipment. Keep these
safety instructions where all those who use the product will read them.
Symbols
Attention: Read User's Guide for cautions and instructions for use
CLASS II
Internal electrical power source

Warnings and Cautions

This product must not be used in the presence of flammable gases.
This product should not be immersed in fluids.
Do not shine the light directly into the patient's eyes.
Ensure that the headband power cord is located in the clips provided. The headlight body
should not be left covered with a cloth or similar.
Federal law restricts this device to sale or order of a physician.
1. Purpose and Features of the product
1.1 Purpose
The headlight is used for examination and surgical operation in multifarious microsurgery.
1.2 Features
Light Source: Our LED without the heat of traditional Halogen headlight. With a color temperature
of 6000 Kelvin, this light supplies bright, white, shadow-free light allowing the doctor to see tissue
characteristics without distortion.
Enjoy the flexibility of operating the headlight using the rechargeable Lithium battery, can use without
the direct power source. It is one of the most comfortable lightweight headlights and suitable for
all kinds of surgery.
The headlight could be used when it is charging.
Has low-battery indicator light.
Adapts to any Binocular Loupes of GIMA.
Smart design, convenient for mobile diagnosis.
2. Operating Instructions
Attach the power cord by means of the clip provided. Place the instrument on your head and adjust for
width and height to that it fits comfortably.
Connect the Headlight to the power adapter. Switch it on and use the headband right or left brightness
control knob to select the required brightness.
Loosen the fixing screw to adjust the light head up and down and backwards or forwards. After adjustment,
re-tighten the screw. The illuminated field of view can be selected by means of the slide control.
3. Maintenance
3.1 Battery charging and replacing
During charging the LEDs operate sequentially, in use they remain switched on. If the LEDs remain
switched off, the unit is non-operational or the battery is switched off. The number of illuminated or
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido