11. SOLUTIONS TO MOST FREQUENT ANOMALIES
ANOMALY
Motor does not
start up
Motor starts up
very slowly and
Damaged condenser. (Single phase
takes long to
reach its
revolutions
Bluntness of the disk segments or
Cutting power
insufficient
The cooling water
does not reach
the disk
Disk premature
damage
Defective cutting
Vibrations
occurrence
POSSIBLE CAUSE
Power supply fault
Damaged switch
Blocked disk
motors)
diamond bands
Inappropriate disk
Motor low potency
Water level low in the tray
Pump blocked
Pump damaged
The pump water tape is closed
Insufficient cooling
Excessive advance
Inappropriate disk
The machine is not aligned
Disk deteriorated or worn-out
Inappropriate disk
Disk oscillation
Disk subjection defect
Wrap the disk
SOLUTION
Check the power supply in the switch
board. Check the position of the thermal
magnet and the differential in the switch
board. Make sure the extension cable is in
a good state and well plugged in both
ends
Substitute it
Remove obstacles preventing the disk
from turning
Substitute it
Effectuate different cuts on an abrasive
material (Sandstone, concrete, stone
emery)
Use appropriate disk for material
Let the motor be checked by technical
service
Fill in water to level
Dismount the tape filter and clean it
Substitute the pump
Open the water tape
Check the cooling
Decrease the advance
Use appropriate disk for material
Align
Change disk
Use appropriate disk for material
Check the state of the disc and mount it
correctly
Make sure the bridles and the motor axis
are well adjusted. Tighten well the nut.
Change the disk