-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identifi ed and
repaired before proceeding.
9. A qualifi ed service agency must check for proper
operating gas pressure upon installation of the
heater.
10. Always use pipe thread compound that is
resistant to propane and natural gas on threaded
connections.
11. Light according to instructions on heater or within
owner's manual.
12. Make sure the heater has the proper gas regula-
tor for the application. A regulator must be con-
nected to the gas supply so that gas pressure
at the inlet to the gas valve is regulated within
the range specifi ed on the dataplate at all times.
Contact your gas supplier, or the L.B. White Co.,
Inc. if you have any questions.
13. This heater is confi gured for use for propane gas
vapor withdrawal only. Do not use the heater
in an propane gas liquid withdrawal system or
application. If you are in doubt, contact the L.B.
White Co., Inc.
14. The heater must be installed so as not to inter-
fere with or obstruct normal exits, emergency
exits, doors and walkways.
15. Railing, fencing or suitable substitute materials
must be used to keep the heating equipment
from any people using and visiting the structure.
16. Eventually, like all electrical/mechanical devices,
the thermostat can fail. Thermostat failure
may result in an underheating condition. The
thermostat should be tested to make sure it
turns the heater on and off within a temperature
differential of ±3°F.
Tradesman Construction Heaters
17. Take time to understand how to operate and
maintain the heater by using this Owner's
Manual. Make sure you know how to shut
off the gas supply to the building and also to
the individual heater. Contact your fuel gas
supplier if you have any questions.
18. Any defects found in performing any of the
service or maintenance procedures must
be eliminated and defective parts replaced
immediately. The heater must be retested by
properly qualifi ed service personnel before
placing the heater back into use.
19. For indoor installation and use only.
Adequate ventilation shall be provided in
accordance with OSHA 29 CFR 1926.154,
Safety Requirements for Temporary and
Portable Space Heating Devices and Equip-
ment, ANSI A10.10, National Fuel Gas Code,
ANSI Z223.1/NFPA54, Liquifi ed Petroleum
Gas Code, NFPA 58 or the Natural gas and
Propane Installation Code, CAN B149.1, as
appropriate.
Owner's Manual • Tradesman
11