CONTROL UNIT
4.2
Inputs and outputs
•
START (using button with N.O. contact or remote control) - starts the automation (opening or closing) on the basis of the
current state and the operating logic settings.
•
STOP (button with N.C. contact) - the input stops the wing immediately. A START pulse is required to continue movement.
The STOP input has priority over all other functions at all times.
•
Closing photocells - these photocells are only enabled on the closing stroke. When triggered they will stop the movement
for 1 second and then start to reopen the gate. These photocells will prevent closing as long as they are covered.
Auxiliary safety edge operating on opening stroke - this is a safety input enabled during the opening stroke. The
•
safety edge will trigger if it touches an obstruction during the opening stroke. The wings will reverse for a short distance
and then stop. To complete the movement which has been interrupted in this way, you must press START. This will complete
the movement in safe mode, i.e. at slow speed with the warning light permanently lit.
•
Auxiliary opening safety photocells - these photocells detect obstacles on the opening and closing strokes; they will
trigger on detecting an obstruction and stop the wings. The movement will only restart when the photocells are uncovered.
After a pause of 1 second, the movement will restart in the original direction.
•
Flashing light - to signal the status of the automation: • fl ashing every 1 sec.
under safe conditions; • fl ashing every 0.5 sec.
pre-fl ashing function must be disabled (
•
Warning light - this is a remote signal indicating the current status of the operator: • light OFF
gate open or opening; • light fl ashing
2 sec pulse type with activation by remote control (
•
Courtesy light - ON when START or PEDESTRIAN START is pressed, with programmable timer (
4.3
T
esting on the display
•
To switch ON the display, press the
quickly. To switch OFF the display, press the YELLOW
button once quickly.
display 1: GATE STATUS
C
= CLOSED
b
= OPENING
A
= OPEN
d
= CLOSED
E
= LOCKED
4.3.1
Error codes and Warnings
Init
•
when
appears press the YELLOW and BLUE simultaneously for approx. 3 seconds.
•
Routine maintenance is required if
Er0
•
ERRORS:
= access to both memories;
5.
PROGRAMMING
IMPORTANT! The gate must be stopped and closed before you can start programming.
WARNING: All input signals will be ignored during programming.
Press and hold RED button
Release the RED button
BLUE
RED when a parameter shown
pressing the BLUE button
Press and hold the RED button for 3 seconds
The parameter has now been modifi ed. More modifi cations can be made before you exit the programming function.
WARNING: modifi cations are only confi rmed when you exit the programming function (display switched OFF).
If the power supply fails for any reason during programming, all the modifi cations you have made will be lost.
To EXIT programming:
Parameters enabling RESET or operations involving MEMORIES: before the modifi cation is confi rmed the display shows
if confi rmation is given (RED button)
IMPORTANT:
routine maintenance required. If the fl ashing light is not used then the
lam
) by setting it to 0 seconds.
gate closing. /Auxiliary output using external relay depending on (
ch1
4
-
YELLOW button once
8
display 2: INPUTS
2
(on=contact closed)
2 = CLOSING PHOTOCELL
4 = PEDESTRIAN START
7
5 = SAFETY DEVICE during OPENING
6
4
6 = START
5
7 = STOP
MAN
fl ashes for approximately 3 seconds when programming is accessed.
Er1
= access to plug-in memory module;
to select a new value
Release the RED button
YELLOW
donE
fl ashes for 3 sec.
BLUE
To select
SWING APRICODE 230
normal functioning; • light ON
) (ex: pedestrian gate electric lock actuation) OR timer (ex: lighting).
PROC
the display shows
displays the fi rst parameter with the value set
scrolls through the parameters
shows the value set (marked by the bullet)
scrolls through the values
3 fl ashes confi rm the modifi cation
the new setting is displayed
returns to the parameters
press the YELLOW button until the display is switched OFF
Er
(positive outcome) o
RED
To confi rm
- 24 -
gate closed; • light ON
ae
ae
).
DISPLAY
1
2
3
4
8 8 8 8
8
display 4: OUTPUTS
2
(on=output active)
1
3
1 = FLASHING
2 = ELECTRIC LOCK
3 = WARNING LIGHT
6
4
4 = WING 2 MOTOR
6 = WING 1 MOTOR
Lrn
fl ashes on display press
Er2
Er3
= photocell test;
= safety edge test.
LO
+ error code in the event of failure.
YELLOW
To exit
operation
) parameter:
START
0
.
SURE
,