Placement And Installation; Regulations And Directives; General Instructions For Placement And Installation - Viadrus ECHEDO Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
GB
GB
4

Placement and installation

4.1

Regulations and directives

EN 13240 + A2
ČSN 73 4230
EN 1443
ČSN 73 4201
EN 13501-1+A1
ČSN 06 1008
4.2

General instructions for placement and installation

Each stove has to be implicitly placed and installed so that there were observed the conditions specified by local regulations or national and
European norms as amended, including their additions, as well as in accordance with instructions specified in this instruction manual.
The stoves are determined for installation in dry premises that are characterized by a valid norm as unaggressive environment without any
explosive are combustible gases.
Before installation of stoves it is necessary to carry out revision of the breast, into which the stove has to be connected, including design and
assessment of the flue channel, which has to provide safety exhaust of flue gases from the connected stove. Only one consumer can be
connected to the flue channel.
At installation it is necessary to provide sufficient access for cleaning of the consumer, the flue gas ducting and the chimney.
In interior where a stove is placed, it is not recommended to place equipment for air exhausting (for example, a fume hood), which could invoke
backward draught and leakage of flue gases into a room. If anyhow this equipment is placed in the interior, it is necessary to provide regulation
of its draught and suction of combustion air from an extern room (a cellar, a technical room, etc.). Only overpressure air conditioning can be
used.
Fig. №. 3
Dismantling the fireplace from the pallet
1.
Open the bottom drawer.
2.
Unlock the stopper on the guiding mechanism and pull the drawer out of the fireplace.
3.
Using the wrench no. 17, unscrew 2 nuts M10 (1) connecting the fireplace and the pallet.
4.
Put the drawer back to the fireplace.
5.
Place the fireplace to the desired location. When placing, rules see chap. 3.4 must be adhered to.
Solid fuels consumers serving for heating of dwelling premises.
Hearths with open and closed fire grates.
Chimneys – General requirements.
Hearths and smoke-flues – Design, implementation and connection of fuel consumers.
Fire protection classification of building products and building structures.
Fire safety of heating equipment.
1.
2.
Nut M10
Washer 10.5
52

Publicidad

Tabla de contenido
loading

Tabla de contenido