4 Instrucciones de programación
4.3.12 12-** Ethernet
Par.
Descripción del parámetro
nº #
12-0* IP Settings
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
4
12-04 DHCP Server
12-05 Lease Expires
12-06 Name Servers
12-07 Domain Name
12-08 Host Name
12-09 Physical Address
12-1* Ethernet Link Parameters
12-10 Link Status
12-11 Link Duration
12-12 Auto Negotiation
12-13 Link Speed
12-14 Link Duplex
12-2* Process Data
12-20 Control Instance
12-21 Process Data Config Write
12-22 Process Data Config Read
12-28 Store Data Values
12-29 Store Always
12-3* EtherNet/IP
12-30 Warning Parameter
12-31 Net Reference
12-32 Net Control
12-33 CIP Revision
12-34 CIP Product Code
12-35 EDS Parameter
12-37 COS Inhibit Timer
12-38 COS Filter
12-8* Other Ethernet Services
12-80 FTP Server
12-81 HTTP Server
12-82 SMTP Service
12-89 Transparent Socket Channel Port
12-9* Advanced Ethernet Services
12-90 Cable Diagnostic
12-91 MDI-X
12-92 IGMP Snooping
12-93 Cable Error Length
12-94 Broadcast Storm Protection
12-95 Broadcast Storm Filter
12-98 Interface Counters
12-99 Media Counters
100
Valor predeterminado
4-set-up (4
ajustes)
[0] MANUAL
2 set-ups
0 N/A
2 set-ups
0 N/A
2 set-ups
0 N/A
2 set-ups
0 N/A
2 set-ups
ExpressionLimit
All set-ups
0 N/A
2 set-ups
0 N/A
2 set-ups
0 N/A
2 set-ups
0 N/A
1 set-up
[0] No Link
1 set-up
ExpressionLimit
All set-ups
[1] Sí
2 set-ups
[0] None
2 set-ups
[1] Full Duplex
2 set-ups
ExpressionLimit
1 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] No
All set-ups
[0] No
1 set-up
0 N/A
All set-ups
[0] No
2 set-ups
[0] No
2 set-ups
ExpressionLimit
All set-ups
ExpressionLimit
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Desactivado
2 set-ups
[0] Desactivado
2 set-ups
[0] Desactivado
2 set-ups
4000 N/A
2 set-ups
[0] Desactivado
2 set-ups
[1] Activado
2 set-ups
[1] Activado
2 set-ups
0 N/A
1 set-up
-1 %
2 set-ups
[0] Broadcast only
2 set-ups
4000 N/A
All set-ups
0 N/A
All set-ups
MG.33.U3.05 - VLT
®
es una marca comercial registrada de Danfoss
®
VLT
Automation Drive FC 300
Manual de Funcionamiento alta potencia
Sólo
Cambio du-
Índice de
FC 302
rante fun-
conversión
cionamiento
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
0
Tipo
Uint8
OctStr[
4]
OctStr[
4]
OctStr[
4]
OctStr[
4]
TimD
OctStr[
4]
VisStr[
48]
VisStr[
48]
VisStr[
17]
Uint8
TimD
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint16
Int8
Uint8
Uint16
Uint16