Electric Shock - Twin-Star International DFH-107-T Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Read Carefully- These instructions are written to help you prevent difficulties
that might arise during installation of heaters. Studying the instructions first may
save you considerable time and money later. Observe the following procedures,
and cut your installation time to a minimum. TO REDUCE RISK OF FIRE OR

ELECTRIC SHOCK;

1. Use minimum 75°C copper wire No.12 AWG only.
2. Heater air flow must be directed parallel to, or away from, adjacent walls.
3. Observe wall, floor, and ceiling clearance requirements.
4. All wiring must conform to national and local electrical codes and the heater
must be grounded as a precaution against possible electrical shock. Heater
circuit must be protected with proper fuse. See Table 1 on page 9.
5. The mounting structure and the anchoring hardware must be capable of
reliable supporting the weight of the heater and, if used, the mounting bracket.
6
.
All electrical power must be disconnected at the main service box before
installing, inspecting, cleaning or servicing the heater. This is a precaution to
prevent serious electrical shock.
Model # DFH-107-T
WARNING
!
E-3