Electrical installation

Mounting steps

Terminal data
E94AZMS0034
E94AZMS0094
E94AZMS0184
E94AZMS0314
PE connection data
E94AZMS0034
E94AZMS0094
E94AZMS0184
E94AZMS0314
Standard device
Cable X302
SSP94FF007
Mounting steps
Proceed as follows to connect the filter:
1. Connect the filter output cable (X302) to terminal X100 of the standard device.
2. Connect the mains cable to terminal X301.
3. Attach the supply−side PE conductor to the PE conductor screw using a ring or
fork−type cable lug.
– The PE connection must comply with EN 61800−5−1.
52
Max. conductor cross−section
2
[mm
]
[AWG]
2.5
4
10
Æ
[mm]
M5
Labelling
Description
1
Filter output conductor (lead with wire end ferrule, colour
BK)
2
3
PE
Output−side PE conductor (lead with M5 fork−type cable
lug, colour GN/YE)
l
Tightening torque
[Nm]
14
0.5 ... 0.6
12
8
1.2 ... 1.5
Starting torque
[Nm]
3.0
!
[lb−in]
4.42 ... 5.31
PH1
10.6 ... 13.3
!
[lb−in]
26.5
SW 8
EDK94AZMS DE/EN/FR/ES/IT 8.0